Page 2
5. Inspect the welded seams by probing the seams thoroughly with a seam probe. Reweld as necessary.
The completed weld should be a minimum of 1.5 in width.
6. Complete the installation by installing a stainless steel hose clamp and approved caulking at the top of
the vertical flashing.
STORAGE
Store in original unopened containers at temperature range of not less than 40°F to no higher than 105°F.
LIMITATIONS
Caution should be taken in transporting the material so as not to allow physical damage such as abrasion
or punctures.
Elvaloy® is a registered trademark of Dupont.